SE141:/MS1

From Metabolonote
jump-to-nav Jump to: navigation, search

Sample Set Information

ID TSE1242
Title Impact of clock-associated Arabidopsis pseudo-response regulators in metabolic coordination.
Description In higher plants, the circadian clock controls a wide range of cellular processes such as photosynthesis and stress responses. Understanding metabolic changes in arrhythmic plants and determining output-related function of clock genes would help in elucidating circadian-clock mechanisms underlying plant growth and development. In this work, we investigated physiological relevance of PSEUDO-RESPONSE REGULATORS (PRR 9, 7, and 5) in Arabidopsis thaliana by transcriptomic and metabolomic analyses. Metabolite profiling using gas chromatography-time-of-flight mass spectrometry demonstrated well-differentiated metabolite phenotypes of seven mutants, including two arrhythmic plants with similar morphology, a PRR 9, 7, and 5 triple mutant and a CIRCADIAN CLOCK-ASSOCIATED 1 (CCA1)-overexpressor line. Despite different light and time conditions, the triple mutant exhibited a dramatic increase in intermediates in the tricarboxylic acid cycle. This suggests that proteins PRR 9, 7, and 5 are involved in maintaining mitochondrial homeostasis. Integrated analysis of transcriptomics and metabolomics revealed that PRR 9, 7, and 5 negatively regulate the biosynthetic pathways of chlorophyll, carotenoid and abscisic acid, and alpha-tocopherol, highlighting them as additional outputs of pseudo-response regulators. These findings indicated that mitochondrial functions are coupled with the circadian system in plants.
Authors Fukushima A, Kusano M, Nakamichi N, Kobayashi M, Hayashi N, Sakakibara H, Mizuno T, Saito K.
Reference Proc Natl Acad Sci U S A. 2009 Apr 28;106(17):7251-6. doi: 10.1073/pnas.0900952106. Epub 2009 Apr 9. Erratum in: Proc Natl Acad Sci U S A. 2009 May 26;106(21):8791.
Comment


Link icon article.png

Analytical Method Details Information

ID MS1
Title GC-TOF MS
Instrument GC:Agilent 6890N MS:LECO Pegasus 4D MS system
Instrument Type
Ionization EI
Ion Mode Positive
Description Each sample was extracted, derivatized, and analyzed by using gas chromatography–time-of-flight (GC-TOF/MS) as described in ref. 48. See also SI Methods(http://www.pnas.org/cgi/data/0900952106/DCSupplemental/Supplemental_PDF#nameddest=STXT).

All the derivatization steps were performed in the vacuum glove box VSC-100 (Sanplatec, Japan) filled with 99.9995% (G3 grade) of dry nitrogen. The analysis of metabolites by GC-TOF/MS was performed as described previously.

Comment_of_details


Link icon article.png