SE148:/MS4
MS Description BioSource amount<br /> We weighed 70 BioSource amount<br /> We weighed 70 mg dry weight (DW) of the lyophilized samples for CE-TOF-MS analysis, 5 mg DW for GC-TOF-MS analysis, 50 mg DW for LC-q-TOF-MS analysis to detect polar metabolites, and 15 mg DW for lipid profiling. <br /> <br /> Extraction and derivatization for GC-TOF-MS<br /> Each sample with a 5-mm zirconia bead was extracted with a concentration of 100 mg DW of powder per ml extraction medium (methanol/chloroform/water [3:1:1 v/v/v]) containing 10 stable isotope reference compounds at 4°C in a mixer mill (MM301; Retsch, Haan, Germany) at a frequency of 15 Hz. Each isotope compound was adjusted to a final concentration of 15 ng per 1-μl injection volume. After 5-min centrifugation at 15,100 x g, a 200-μl aliquot of the supernatant was transferred to a glass insert vial. The extracts were evaporated to dryness in an SPD2010 SpeedVac® concentrator (Thermo Fisher, Scientific, Waltham, MA, USA). We used extracts from 1-mg DW samples for derivatization, i.e., methoxymation and silylation. For methoxymation, 30 μl of methoxyamine hydrochloride (20 mg/ml in pyridine) were added to the sample. After 17 h of derivatization at room temperature the sample was trimethylsilylated for 1 h using 30 µl of MSTFA at 37°C with shaking. All derivatization steps were performed in a vacuum glove box VSC-100 (Sanplatec, Osaka, Japan) filled with 99.9995% (G3 grade) dry nitrogen.<br /> <br /> GC-TOF-MS conditions<br /> Using the splitless mode of a CTC CombiPAL autosampler (CTC Analytics, Zwingen, Switzerland), 1 μl of each sample (equivalent to 1.4 µg DW) was injected into an Agilent 6890N gas chromatograph (Agilent Technologies, Wilmingston, DE, USA) featuring a 30 m × 0.25 mm inner diameter fused-silica capillary column and a chemically bound 0.25-μl film Rxi-5 Sil MS stationary phase (RESTEK, Bellefonte, PA, USA) with a tandem connection to a fused silica tube (1 m, 0.15 mm). An MS column change interface (ms NoVent-J; SGE, Yokohama, Japan) was used to prevent air and water from entering the MS during column change-over. Helium was the carrier gas at a constant flow rate of 1 ml min-1. The temperature program for GC-MS analysis started with a 2-min isothermal step at 80°C followed by 30°C temperature-ramping to a final temperature of 320°C that was maintained for 3.5 min. The transfer line and the ion source temperatures were 250 and 200°C, respectively. Ions were generated by a 70-eV electron beam at an ionization current of 2.0 mA. The acceleration voltage was turned on after a solvent delay of 222 sec. Data acquisition was on a Pegasus IV TOF mass spectrometer (LECO, St. Joseph, MI, USA); the acquisition rate was 30 spectra s-1 in the mass range of a mass-to-charge ratio of m/z = 60–800. Alkane standard mixtures (C8 - C20 and C21 - C40) purchased from Sigma-Aldrich (Tokyo, Japan) were used for calculating the retention index (RI) (Schauer N, et al. (2005) GC-MS libraries for the rapid identification of metabolites in complex biological samples. FEBS lett 579(6):1332-1337). For quality control we injected methylstearate into every 6th sample. The sample run order was randomized in single-sequence analyses. We analyzed the standard compound mixtures using the same sequence analysis procedures.<br /> <br /> lysis procedures.<br /> <br />
MS ID MS4  +
MS Instrument GC:Agilent 6890N gas chromatograph (Agilent Technologies, Wilmingston, USA) <br />MS:Pegasus IV TOF mass spectrometer (LECO, St. Joseph, MI, USA)  +
MS Ion Mode Positive  +
MS Ionization EI  +
MS Title GC-TOF-MS  +
Modification dateThis property is a special property in this wiki. 24 April 2018 08:05:27  +
hide properties that link here 
  No properties link to this page.
 

 

Enter the name of the page to start browsing from.
Personal tools
View and Edit Metadata
Variants
Views
Actions
Toolbox