Browse wiki

jump-to-nav Jump to: navigation, search
SE57:/MS01
MS Description <Automated liquid handling for sample p <Automated liquid handling for sample preparation><br /> The plant tissue samples were frozen in liquid nitrogen, quenched using a Mixer Mill (MM300, Retsch, Hann, Germany) as previously reported ( Hirai et al. 2007 ), and the extraction buffer (80% MeOH) was added. The resulting extracts consisted of 400 μ l with 20 mg ml –1 (fresh weight) of tissue. The extracts were transferred and treated using an ALHS as follows (Supplementary Fig. S1): 350 μ l of each plant extract were transferred to a 96-well plate, and the solutions were dried under N 2 gas using a 96-well format spray instrument (40°C, 25 min and 30°C, 20 min). The dried samples were dissolved in 350 μ l of H 2 O using a vortex system (1,300 r.p.m., 6 min), and then fi ltered through a 96-well filter [Captiva 96-well Filter Plate (pore size 0.45 μ m, polyvinylidene fl uoride), Varian, CA, USA], using a vacuum manifold with the following program: 30 s, 50 Hpa; 20 s, 100 Hpa; 20 s, 200 Hpa; 30 s, 300 Hpa; and 60 s, 300 Hpa. Plate handling was carried out automatically using robot arms (iSWAP, Hamilton). <br /><br /> <Acquisition of ESI-MS and ESI-MS/MS data><br /> All the solutions of authentic compounds (250 μ M) were transferred from 10 ml vials to 1.2 ml glass inserts in 96-well plates (Webseal system, GL Sciences, Tokyo, Japan) and diluted to 50 pmol μ l –1 with H 2 O using an ALHS (Microlab STARplus, Hamilton, Reno, NV, USA). The solutions (20 μ l aliquots containing 1 nmol of compound) were analyzed by the flow injection method using a CTC-PAL injection system (AMR, Tokyo, Japan) and a Waters GI Pump solvent system (Waters, Milford, MA, USA) consisting of: 0.05 ml min –1 flow using a micro splitter (GL Sciences), 80% acetonitrile (0.1% formic acid) and 20% water (0.1% formic acid), with a 2.5 min cycle in the isocratic mode. The ionized authentic compounds were detected by TQMS (TQD, Waters) according to the following conditions: capillary voltage +3.0 keV or –2.8 keV, CV 10–60 eV (six levels), source temperature 120°C, desolvation temperature 350°C, cone gas fl ow 50 l h –1 , desolvation gas fl ow 600 l h –1 and CE 10–60 eV (six levels). A total of 61,920 spectra of 860 compounds were obtained.The optimal MRM conditions, including positive/negative polarity (e.g. [M] + , [M + H] + , [M] – , [M – H] – ), m / z of precursor ion and product ion, and optimal CV and CE were determined automatically for 497 of these compounds using the software QuanOptimize (Waters).<br /><br /> <UPLC-TQMS analysis><br /> The UPLC (Waters) conditions were manually optimized based on the separation patterns of 12 methionine-derived glucosinolates and were as follows: flow rate 0.24 ml min –1 ; solvents A, 0.1% formic acid in water and B, 0.1% formic acid in acetonitrile; gradient program of B (0 min, 0%; 0.25 min, 0%; 0.4 min, 9%; 0.8 min, 17%; 1.9 min, 100%; 2.1 min, 100%;2.11 min, 0%); 3 min cycles with a temperature of 38°C.The TQMS detection conditions were the same as those for FIA-TQMS, except that the source temperature was 130°C.<br /> source temperature was 130°C.<br />
MS ID MS01  +
MS Instrument Waters Xevo TQD, UPLC (Waters)  +
MS Instrument Type UPLC-QTOF-MS  +
MS Ion Mode Positive and Negative  +
MS Ionization ESI  +
MS Title Acquisition of ESI-MS and ESI-MS/MS data, UPLC-TQMS analysis  +
Modification dateThis property is a special property in this wiki. 23 April 2018 10:07:59  +
hide properties that link here 
  No properties link to this page.
 

 

Enter the name of the page to start browsing from.
Personal tools
View and Edit Metadata
Variants
Views
Actions
Toolbox