SE46:/MS02
MS Description Among these harvested plants, the plants t Among these harvested plants, the plants that had fresh weight over 13 mg were used for GC-TOF/MS analysis (WT, n = 17; mto1, n = 13; and tt4, n = 20). For liquid chromatography-quadrupole-time-of-flight/mass spectrometry (LC-Q-TOF/MS) analysis, 3 biological replicates were prepared. All the plant materials were frozen immediately in liquid nitrogen to quench the enzymatic activity.<br /><br /> LC-Q-TOF/MS analysis<br /> Frozen leaves were homogenized in 5-μl extraction solvent (methanol/H2O [4:1 v/v]) per mg fresh weight of tissues by using a mixer mill at a frequency of 20 Hz for 3 min at 4°C. After centrifugation at 12,000 × g, the cell debris was discarded, and the extracts were centrifuged again. These supernatants were immediately used for flavonoid analysis. For flavonoid profiling, Waters Acquity UPLC™ system (Waters Co., Massachusetts, USA) fitted with a Q-ToF Premier mass spectrometer (Micromass MS Technologies, Manchester, UK) was used. Ultra-performance liquid chromatography (UPLC) was carried out on a UPLC™ BEH C18 column (100-mm length × 2.1-mm inner diameter, 1.7-μm particles, Waters Co.) at a flow rate of 0.5 ml/min at 35°C. The elution gradient comprised solvent A (0.1% trifluoroacetic acid in H2O) and solvent B (0.1% trifluoroacetic acid in acetonitrile) and the elution profile – 0 min, 100% A; 5 min, 11% B; 20 min, 13% B; 24 min, 100% B – using linear gradients in between the time points. A photodiode array (PDA) detector was used for the detection of UV-visible absorption in the range of 210–500 nm. The TOF mass analyzer was used for the detection of flavonoid glycosides [M+H]+ and fragment ions peak in a positive ion mode scan. The desolvation temperature was 450°C with a nitrogen gas flow rate of 600 l/h, capillary spray at 3.2 kV, source temperature at 150°C, and cone voltage at 35 V.<br /> The peaks in the plant extracts were identified based on retention times, UV visible absorption spectra, and mass fragmentation by tandem MS analysis as reported (Yonekura-Sakakibara et al. 2007). The amounts of each kaempferol glycoside and sinapoyl derivative were calculated using kaempferol (at 340 nm) or sinapic acid (at 340 nm) as a standard, respectively. d (at 340 nm) as a standard, respectively.
MS ID MS02  +
MS Instrument LC, Waters Acquity UPLC system; MS, Q-ToF Premier mass spectrometer  +
MS Instrument Type UPLC-QTOF-MS  +
MS Ion Mode positive  +
MS Ionization ESI  +
MS Title LC-q-TOF-MS  +
Modification dateThis property is a special property in this wiki. 23 April 2018 08:49:51  +
hide properties that link here 
  No properties link to this page.
 

 

Enter the name of the page to start browsing from.
Personal tools
View and Edit Metadata
Variants
Views
Actions
Toolbox