SE17:/S01/M01/D02
From Metabolonote
Sample Set Information
ID | SE17 |
---|---|
Title | Comparison of leaf metabolites among spinach varieties 2 |
Description | Investigation of Spinacia oleracea leaf metabolites. 10 cultivers (Houyou, Jiroumaru, Kanaji, Kurohaminstarland, Mahoroba, Nihon, Rakusyuu, Saladahourensou, Solomon and ,Wasesaradaakari) and 3 replicates data are examined. |
Authors | Takeshi Ara 1, Yoshiki Nagashima 1, Naoki Yamamoto 1, Kunihiro Suda 1, Mitsuo Enomoto 1, Nozomu Sakurai 1, Hideyuki Suzuki 1, Tatsuya Suzuki 2, Daisuke Shibata 1, 1: Kazusa DNA Research Institute, 2: Chiba Prefectural Agriculture Research Center |
Reference | Direct Submittion |
Comment | version 1 |
Sample Information
ID | S01 |
---|---|
Title | Spinacia oleracea Houyou Leaf |
Organism - Scientific Name | Spinacia oleracea |
Organism - ID | NCBI taxonomy:3562 |
Compound - ID | |
Compound - Source | |
Preparation | Spinacia oleracea are grown at agricultural field in natural conditions. |
Sample Preparation Details ID | |
Comment | [KomicMarket ID] KSBA_63 |
Analytical Method Information
ID | M01 |
---|---|
Title | LC-FTICR-MS, ESI Positive analysis |
Method Details ID | MS1 |
Sample Amount | 6.7mg |
Comment | [MassBase ID] MDLC1_36278 |
The raw (binary) and near-raw (text) files of this analysis are available at MassBase.
Analytical Method Details Information
ID | MS1 |
---|---|
Title | LC-FT-ICR-MS ESI positive method 1 |
Instrument | Agilent1100 HPLC (Agilent), LTQ-FT (Thermo Fisher Scientific) |
Instrument Type | LC-FTICR-MS |
Ionization | ESI |
Ion Mode | Positive |
Description | Harvested sample is frozen by liquid N2 and resulting powder (100mg) are solved in 300uL 80% methanol solution. 20uL sample is injected into HPLC after 0.2um membrane filter treatment. HPLC conditions: Agilent 1100 series (Agilent), Column: TSKgel-100V (4.6 x 250 mm, 5 micrometer; TOSOH), Solvent: A; 0.1% formic acid aq. B; ACN (addition 0.1% formic acid fc.), Gradient: (B);3 to 97% (0.0 to 45.0 min), 97% (45.1 to 50.0 min), 3% (50.1 to 57.0 min), Column temp.: 40 degree C, Flow rate=0.5mL/min, PDA: 200-650 nm (2 nm step). FT-ICR-MS conditions: Filter 1: FTMS + c norm !corona !pi res=100000 o(100.0-1500.0); 2: ITMS + c norm !corona !pi Dep MS/MS Most intense ion from (1); 3: ITMS + c norm !corona !pi Dep MS/MS 2nd most intense ion from (1); 4: ITMS + c norm !corona !pi Dep MS/MS 3rd most intense ion from (1); 5: ITMS + c norm !corona !pi Dep MS/MS 4th most intense ion from (1); 6: ITMS + c norm !corona !pi Dep MS/MS 5th most intense ion from (1)., Rejected mass=235.1800, 376.0400, 378.0400, 380.0300, 540.6000, 609.2800, 610.2800, 726.3600, 810.4100, 811.9200, 818.4100, 1101.6900, 1118.7200, 1118.7200, 1119.7200, 1123.6800. |
Comment_of_details |
The data can be compared with the data obtained by the method SE13_MS1
Data Analysis Information
ID | D02 |
---|---|
Title | PowerGet data analysis for KomicMarket2 |
Data Analysis Details ID | DS2 |
Recommended decimal places of m/z | 6|ITMS 2 |
Comment |
Data Analysis Details Information
ID | DS2 |
---|---|
Title | PowerGet analysis for detection of all peaks (B3) |
Description | Raw data files are converted to text file by MSGet software without cut off value and peaks are extracted from the text files by PowerFT with parameters (intensity cut off=5000, peak selection filter is default, intensity cut off in peak assignment=1000). The replicates data are aligned by PowerMatch with blank data. The alignment is manually edited. Assigned peaks observed in multiple replicate samples are selected for annotation process. |
Comment_of_details |