SE40:/S29/M03

From Metabolonote
jump-to-nav Jump to: navigation, search

Sample Set Information

ID SE40
Title Comparison of fruit metabolites among tomato cultivars
Description Investigation of Tomato fruits metabolites. 28 cultivers and 3 replicates data are examined.
Authors Takeshi Ara 1, Shingo Takahashi 1,3, Naoko Waki 1,3, Nozomu Sakurai 2, Haruya Takahashi 1, Shinsuke Mohri 1, Kunimi Suda 2, Keishi Ozawa 2, Takisawa Rihito 4, Akira Kitajima 4, Yasuki Matsumura 1, Teruo Kawada 1, Daisuke Shibata 1, 2, 1:Graduate School of Agriculture, Kyoto University, Japan, 2:Kazusa DNA Research Institute, Kazusa Kamatari 2-6-7, Kisarazu, Chiba 292-0818, Japan, 3:Kagome Co., Ltd., Japan, 4:Experimental Farm of Kyoto University, Japan
Reference Ara T. et al. (2021) Plant Direct 5(4) e00318
Comment version 1


Link icon article.png

TOMATOMET: http://metabolites.in/tomato-fruits/

PGDBj: http://pgdbj.jp/plantdb/plantinfo.html?ln=en&cmd=entry&ppid=t4081

Sample Information

ID S29
Title Mock
Organism - Scientific Name
Organism - ID
Compound - ID
Compound - Source
Preparation
Sample Preparation Details ID
Comment

Analytical Method Information

ID M03
Title LC-Orbitrap-MS, ESI Positive analysis
Method Details ID MS1
Sample Amount
Comment [MassBase ID] MDLC1_46848


Link icon database.png Link icon massbase.png

The raw (binary) and near-raw (text) files of this analysis are available at MassBase.

Analytical Method Details Information

ID MS1
Title LC-Orbitrap-MS ESI positive method 1
Instrument Agilent1200 HPLC (Agilent), LTQ-Orbitrap (Thermo Fisher Scientific)
Instrument Type LC-Orbitrap-MS
Ionization ESI
Ion Mode Positive
Description Harvested sample is frozen by liquid N2 and resulting powder (100mg) are solved in 300uL 80% methanol solution. 5uL sample is injected into HPLC after 0.2um membrane filter treatment. HPLC conditions: Agilent 1200 series (Agilent), Column: TSKgel ODS-100V (3 x 50 mm, 5 micrometer; TOSOH), Solvent: A; 0.1% formic acid aq. B; ACN (addition 0.1% formic acid fc.), Gradient: (B) 0 to 3% for 15 min, 3 to 97% for 20 min, 97 to 3% for 0.1 min, and 3% for 25 min., Column temp.: 40 degree C, Flow rate=0.4mL/min, PDA: 190-950 nm (2 nm step). Orbitrap-MS conditions: Filter 1: FTMS + c norm !corona !pi res=60000 o(100.0-1500.0); 2: ITMS + c norm !corona !pi Dep MS/MS Most intense ion from (1); 3: ITMS + c norm !corona !pi Dep MS/MS 2nd most intense ion from (1); 4: ITMS + c norm !corona !pi Dep MS/MS 3rd most intense ion from (1); 5: ITMS + c norm !corona !pi Dep MS/MS 4th most intense ion from (1).
Comment_of_details